Print | Rate this content

Advisory: HPE Smart Array Controllers - Data in Write-Backed Cache on a Gen9 Px4x Controller May Be Lost After an Unexpected System Shutdown

SUPPORT COMMUNICATION - CUSTOMER ADVISORY

Document ID: c05158732

Version: 1

Advisory: HPE Smart Array Controllers - Data in Write-Backed Cache on a Gen9 Px4x Controller May Be Lost After an Unexpected System Shutdown
NOTICE: The information in this document, including products and software versions, is current as of the Release Date. This document is subject to change without notice.

Release Date: 2016-06-01

Last Updated: 2016-08-23


DESCRIPTION

On certain HPE Smart Array Gen 9 Px4x controllers, a 1793 or 1797 message may be displayed at Power-On Self-Test (POST) following a backup and restore operation of the Flash Backed Write Cache (FBWC). When this occurs, the FBWC may become disabled.

One of the following POST messages will be displayed only on the first reboot after an unexpected shutdown:

  • 1793-Slot # Drive Array Write-Back Cache Backup Previously Failed. Caching is disabled.
  • 1793-Slot # Drive Array Data in Write-Back Cache has been Lost. Write-Back Cache Backup Failed.
  • 1793-Slot # Drive Array Data in Write-Back Cache has been Lost. Action: Verify the integrity of the data on the drive. Backup and restore data if necessary. Perform orderly shutdowns to avoid leaving data in the cache.

One of the following messages will be displayed during POST every time when the server is rebooted:

  • 1797-Slot # Drive Array Write-Back Cache Read Error Occurred - Data in Cache has been lost. Caching is disabled.
  • 1797-Slot # Drive Array Write-Back Cache Backup Previously Failed. Caching is disabled.
  • 1797-Slot # Drive Array Write-Back Cache Backup Previously Failed. Caching is disabled. Action: Replace the Cache Module.
  • 1797-Slot # Drive Array Write-Back Cache Restore Previously Failed. Caching is disabled. Action: Replace the Cache Module.
NOTE: This affects only controllers that have cache embedded.

SCOPE

Any ProLiant server configured with an HPE Smart Array Gen9 Px4xar or Px4xbr controller.

RESOLUTION

Update the Smart Array Controller firmware to version 4.02 in order to proactively prevent this issue. Upgrade to HPE Smart Array Firmware Version 4.02 by following the steps below:

  1. Click the following link:

    http://h20566.www2.hpe.com/portal/site/hpsc

  2. Enter a product name (e.g., "P244br") in the text field under Enter a Product Name or Number.
  3. Click Go.
  4. Select the appropriate product model from the Results list (if prompted).
  5. Click the "drivers, software & firmware" hyperlink under the Download Options tab.
  6. Select the system's specific operating system from the Operating Systems dropdown menu.
  7. Click the category Firmware- Storage Controller.
  8. Select the latest release of Online ROM Flash Component Version 4.02 (or later).
  9. Click Download.

If the issue has already occurred, replace the HPE Smart Array controller if the Smart Array Controller cache is embedded on the Smart Array controller board. For further assistance, refer to the following support information:

In North America, contact HPE Customer Support at 1-844-806-3425.

OR

For HPE Customer Support, click on the following URL for Customer Support.

http://www8.hp.com/us/en/hpe/contact/support.html

NOTE: For Gen9 controllers that do not have cache embedded, the cache is not replaceable by itself. The controller and cache must be replaced at the same time.




RECEIVE PROACTIVE UPDATES : Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HPE Subscriber's Choice. Sign up for Subscriber's Choice at the following URL: Proactive Updates Subscription Form.

NAVIGATION TIP : For hints on navigating HPE.com to locate the latest drivers, patches, and other support software downloads for ProLiant servers and Options, refer to the Navigation Tips document .

SEARCH TIP : For hints on locating similar documents on HPE.com, refer to the Search Tips document .


Hardware Platforms Affected: HP Smart Array P244br Controller, HP Smart Array P246br Controller, HP Smart Array P440ar Controller, HPE Smart Array P840ar Controller
Operating Systems Affected: Not Applicable
Software Affected: Not Applicable
Support Communication Cross Reference ID: IA05158732
©Copyright 2017 Hewlett Packard Enterprise Company, L.P.
Hewlett Packard Enterprise Company shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind. To the extent permitted by law, neither HPE nor its affiliates, subcontractors or suppliers will be liable for incidental, special or consequential damages including downtime cost; lost profits; damages relating to the procurement of substitute products or services; or damages for loss of data, or software restoration. The information in this document is subject to change without notice. Hewlett Packard Enterprise Company and the names of Hewlett Packard Enterprise Company products referenced herein are trademarks of Hewlett Packard Enterprise Company in the United States and other countries. Other product and company names mentioned herein may be trademarks of their respective owners.

Provide feedback